Heatshrink End Caps
Ref: SWRSFM167
pricecost
|
|
Heatshrink End Caps, prices are per pack of 100 04/07 jj
Property - Operating temperature, Test Method - IEC 216, Standard Value -55c-100c
Property - Tensile strength, Test Method ASTM-D-2671, Standard Value 13MPa
Property - Tensile strength after thermal aging, Test Method- ASTM-D-2671 (120c/168hrs), Standard Value 11MPa
Property- Elongation at break, Test Method ASTM-D-2671, Standard Value 300%
Property- Elongation at break after thermal aging, Test Method- ASTM-D-2671 (120c/168hrs) Standard Value 230%
Property- Longitudinal Shrinkage, Test Method- UL 224, Standard Value- 10%
Property- Eccentricity, Test Method- ASTM-D-2671, Standard Value 30%
Property- Water absorption, Test Method- ISO 62, Standard Value 0.1%
Property- Volume Resistance, Test Method- IEC 93, Standard Value 1x10.cm
Property- Dielectric strength, Test Method IEC 243, Standard Value 20kv/mm
Property- Resistance to stress crackimg, Test Method ASTM-D-1693 (50c), Standard Value- no cracking
Property- Resistance to fungus and decay, Test Metyhod ISO 846, Standard Value-pass
Property- Minimum shrink temperature, Standard Value 100c
Property- Minimum fully recovered temperature, Standard Value-130c
04/07 jj
click to enlarge